MainCode/adalm1000_logger.py aktualisiert
Entladephase analog zur Ladephase verstärken
Doppelten msg_box Aufruf entfernen
(D)
This commit is contained in:
parent
f779d97397
commit
bc77ae2f6b
@ -596,67 +596,114 @@ class BatteryTester(QMainWindow):
|
|||||||
|
|
||||||
def execute_charge_phase(self, current, target_voltage):
|
def execute_charge_phase(self, current, target_voltage):
|
||||||
"""Führt die Ladephase durch"""
|
"""Führt die Ladephase durch"""
|
||||||
|
if not hasattr(self, 'dev') or not self.session_active:
|
||||||
|
self.error_signal.emit("Device not connected")
|
||||||
|
return
|
||||||
self.test_phase = "Laden"
|
self.test_phase = "Laden"
|
||||||
self.phase_label.setText(self.test_phase)
|
self.phase_label.setText(self.test_phase)
|
||||||
self.status_bar.setText(f"Laden auf {target_voltage}V @ {current:.3f}A")
|
self.status_bar.setText(f"Laden auf {target_voltage}V @ {current:.3f}A")
|
||||||
|
|
||||||
self.measuring = True
|
self.measuring = True
|
||||||
self.dev.channels['A'].mode = pysmu.Mode.SIMV
|
try:
|
||||||
self.dev.channels['A'].constant(current)
|
# Reset channel first
|
||||||
self.charge_capacity = 0.0
|
self.dev.channels['A'].mode = pysmu.Mode.HI_Z
|
||||||
self.charge_capacity_label.setText("0.000")
|
|
||||||
last_update = time.time()
|
|
||||||
|
|
||||||
while self.test_running and not self.request_stop:
|
|
||||||
if not self.voltage_data:
|
|
||||||
time.sleep(0.1)
|
|
||||||
continue
|
|
||||||
|
|
||||||
now = time.time()
|
|
||||||
delta_t = now - last_update
|
|
||||||
last_update = now
|
|
||||||
|
|
||||||
measured_current = abs(self.current_data[-1])
|
|
||||||
self.charge_capacity += measured_current * delta_t / 3600
|
|
||||||
self.charge_capacity_label.setText(f"{self.charge_capacity:.4f}")
|
|
||||||
|
|
||||||
current_voltage = self.voltage_data[-1]
|
|
||||||
if current_voltage >= target_voltage or self.request_stop:
|
|
||||||
break
|
|
||||||
|
|
||||||
time.sleep(0.1)
|
time.sleep(0.1)
|
||||||
|
|
||||||
|
# Configure for current sourcing
|
||||||
|
self.dev.channels['A'].mode = pysmu.Mode.SIMV
|
||||||
|
time.sleep(0.05)
|
||||||
|
self.dev.channels['A'].constant(current)
|
||||||
|
time.sleep(0.1) # Allow settling time
|
||||||
|
actual_current = self.dev.channels['A'].current
|
||||||
|
if abs(actual_current - current) > 0.01: # 10mA tolerance
|
||||||
|
self.error_signal.emit(f"Current mismatch: {actual_current:.3f}A vs {current:.3f}A")
|
||||||
|
|
||||||
|
self.charge_capacity = 0.0
|
||||||
|
self.charge_capacity_label.setText("0.000")
|
||||||
|
last_update = time.time()
|
||||||
|
|
||||||
|
while self.test_running and not self.request_stop:
|
||||||
|
if not self.voltage_data:
|
||||||
|
time.sleep(0.1)
|
||||||
|
continue
|
||||||
|
|
||||||
|
now = time.time()
|
||||||
|
delta_t = now - last_update
|
||||||
|
last_update = now
|
||||||
|
|
||||||
|
measured_current = abs(self.current_data[-1])
|
||||||
|
self.charge_capacity += measured_current * delta_t / 3600
|
||||||
|
self.charge_capacity_label.setText(f"{self.charge_capacity:.4f}")
|
||||||
|
|
||||||
|
current_voltage = self.voltage_data[-1]
|
||||||
|
if current_voltage >= target_voltage or self.request_stop:
|
||||||
|
break
|
||||||
|
|
||||||
|
time.sleep(0.1)
|
||||||
|
|
||||||
|
except Exception as e:
|
||||||
|
self.error_signal.emit(f"Charge error: {str(e)}")
|
||||||
|
|
||||||
def execute_discharge_phase(self, current, target_voltage):
|
def execute_discharge_phase(self, current, target_voltage):
|
||||||
"""Führt die Entladephase durch"""
|
"""Führt die Entladephase durch"""
|
||||||
|
if not hasattr(self, 'dev') or not self.session_active:
|
||||||
|
self.error_signal.emit("Device not connected")
|
||||||
|
return
|
||||||
|
|
||||||
self.test_phase = "Entladen"
|
self.test_phase = "Entladen"
|
||||||
self.phase_label.setText(self.test_phase)
|
self.phase_label.setText(self.test_phase)
|
||||||
self.status_bar.setText(f"Entladen auf {target_voltage}V @ {current:.3f}A")
|
self.status_bar.setText(f"Entladen auf {target_voltage}V @ {current:.3f}A")
|
||||||
|
|
||||||
self.measuring = True
|
self.measuring = True
|
||||||
self.dev.channels['A'].mode = pysmu.Mode.SIMV
|
try:
|
||||||
self.dev.channels['A'].constant(-current)
|
# Reset channel first
|
||||||
self.capacity_ah = 0.0
|
self.dev.channels['A'].mode = pysmu.Mode.HI_Z
|
||||||
self.capacity_label.setText("0.000")
|
|
||||||
last_update = time.time()
|
|
||||||
|
|
||||||
while self.test_running and not self.request_stop:
|
|
||||||
if not self.current_data:
|
|
||||||
time.sleep(0.1)
|
|
||||||
continue
|
|
||||||
|
|
||||||
now = time.time()
|
|
||||||
delta_t = now - last_update
|
|
||||||
last_update = now
|
|
||||||
|
|
||||||
measured_current = abs(self.current_data[-1])
|
|
||||||
self.capacity_ah += measured_current * delta_t / 3600
|
|
||||||
self.capacity_label.setText(f"{self.capacity_ah:.4f}")
|
|
||||||
|
|
||||||
current_voltage = self.voltage_data[-1]
|
|
||||||
if current_voltage <= target_voltage or self.request_stop:
|
|
||||||
break
|
|
||||||
|
|
||||||
time.sleep(0.1)
|
time.sleep(0.1)
|
||||||
|
|
||||||
|
# Configure for current sinking
|
||||||
|
self.dev.channels['A'].mode = pysmu.Mode.SIMV
|
||||||
|
time.sleep(0.05)
|
||||||
|
self.dev.channels['A'].constant(-current)
|
||||||
|
time.sleep(0.1)
|
||||||
|
|
||||||
|
# Current verification
|
||||||
|
samples = self.dev.read(5)
|
||||||
|
measured_current = -np.mean([s[0][1] for s in samples])
|
||||||
|
if abs(measured_current - current) > 0.02:
|
||||||
|
self.error_signal.emit(f"Entladestrom Abweichung: {measured_current:.3f}A vs {current:.3f}A")
|
||||||
|
|
||||||
|
self.capacity_ah = 0.0
|
||||||
|
self.capacity_label.setText("0.000")
|
||||||
|
last_update = time.time()
|
||||||
|
|
||||||
|
while self.test_running and not self.request_stop:
|
||||||
|
if not self.current_data:
|
||||||
|
time.sleep(0.1)
|
||||||
|
continue
|
||||||
|
|
||||||
|
now = time.time()
|
||||||
|
delta_t = now - last_update
|
||||||
|
last_update = now
|
||||||
|
|
||||||
|
measured_current = abs(self.current_data[-1])
|
||||||
|
self.capacity_ah += measured_current * delta_t / 3600
|
||||||
|
self.capacity_label.setText(f"{self.capacity_ah:.4f}")
|
||||||
|
|
||||||
|
current_voltage = self.voltage_data[-1]
|
||||||
|
if current_voltage <= target_voltage or self.request_stop:
|
||||||
|
break
|
||||||
|
|
||||||
|
time.sleep(0.1)
|
||||||
|
|
||||||
|
except Exception as e:
|
||||||
|
self.error_signal.emit(f"Discharge error: {str(e)}")
|
||||||
|
finally:
|
||||||
|
# Sicherstellen, dass der Kanal zurückgesetzt wird
|
||||||
|
try:
|
||||||
|
self.dev.channels['A'].mode = pysmu.Mode.HI_Z
|
||||||
|
self.dev.channels['A'].constant(0)
|
||||||
|
except Exception as e:
|
||||||
|
print(f"Error resetting channel: {e}")
|
||||||
|
|
||||||
def execute_rest_phase(self, phase_name):
|
def execute_rest_phase(self, phase_name):
|
||||||
"""Führt eine Ruhephase durch"""
|
"""Führt eine Ruhephase durch"""
|
||||||
@ -742,10 +789,9 @@ class BatteryTester(QMainWindow):
|
|||||||
self.stop_button.setEnabled(False)
|
self.stop_button.setEnabled(False)
|
||||||
self.start_button.setEnabled(True)
|
self.start_button.setEnabled(True)
|
||||||
|
|
||||||
# Testdaten finalisieren
|
self.finalize_test(show_message=False)
|
||||||
QTimer.singleShot(100, self.finalize_test)
|
|
||||||
|
|
||||||
def finalize_test(self):
|
def finalize_test(self, show_message=True):
|
||||||
"""Finale Bereinigung nach Testende mit verbessertem Fenster-Handling"""
|
"""Finale Bereinigung nach Testende mit verbessertem Fenster-Handling"""
|
||||||
try:
|
try:
|
||||||
# 1. Protokolldaten schreiben (mit zusätzlichem Lock)
|
# 1. Protokolldaten schreiben (mit zusätzlichem Lock)
|
||||||
@ -767,31 +813,15 @@ class BatteryTester(QMainWindow):
|
|||||||
print(f"Fehler beim Schließen der Protokolldatei: {e}")
|
print(f"Fehler beim Schließen der Protokolldatei: {e}")
|
||||||
|
|
||||||
# 3. Benachrichtigung anzeigen (mit Fokus-Sicherung)
|
# 3. Benachrichtigung anzeigen (mit Fokus-Sicherung)
|
||||||
msg_box = QMessageBox(self) # Expliziter Parent
|
if show_message: # Only show if explicitly requested
|
||||||
msg_box.setWindowFlags(msg_box.windowFlags() |
|
msg_box = QMessageBox(self)
|
||||||
Qt.WindowStaysOnTopHint | # Immer im Vordergrund
|
msg_box.setWindowFlags(msg_box.windowFlags() |
|
||||||
Qt.MSWindowsFixedSizeDialogHint) # Besseres Verhalten unter Windows
|
Qt.WindowStaysOnTopHint)
|
||||||
|
msg_box.setIcon(QMessageBox.Information)
|
||||||
|
msg_box.setWindowTitle("Test abgeschlossen")
|
||||||
|
msg_box.setText(f"Test beendet\nZyklen: {self.cycle_count}")
|
||||||
|
msg_box.exec_()
|
||||||
|
|
||||||
msg_box.setIcon(QMessageBox.Information)
|
|
||||||
msg_box.setWindowTitle("Test abgeschlossen")
|
|
||||||
msg_box.setText(
|
|
||||||
f"Test wurde sicher beendet.\n\n"
|
|
||||||
f"Entladekapazität: {self.capacity_ah:.3f}Ah\n"
|
|
||||||
f"Abgeschlossene Zyklen: {self.cycle_count}"
|
|
||||||
)
|
|
||||||
|
|
||||||
# Sicherstellen, dass das Fenster sichtbar wird
|
|
||||||
msg_box.raise_()
|
|
||||||
msg_box.activateWindow()
|
|
||||||
|
|
||||||
# Non-blocking anzeigen und Fokus erzwingen
|
|
||||||
QTimer.singleShot(100, lambda: (
|
|
||||||
msg_box.show(),
|
|
||||||
msg_box.raise_(),
|
|
||||||
msg_box.activateWindow()
|
|
||||||
))
|
|
||||||
msg_box.exec_()
|
|
||||||
|
|
||||||
except Exception as e:
|
except Exception as e:
|
||||||
print(f"Kritischer Fehler in finalize_test: {e}")
|
print(f"Kritischer Fehler in finalize_test: {e}")
|
||||||
finally:
|
finally:
|
||||||
|
|||||||